Welcome to Shandong Proud Measurement&Control Technology CO., LTD!

186-1523-0752

0531-88975421

Popular product search:
Click to enlarge

CL543B thermocouple and RTD calibrator

Product Introduction:

CL543B thermocouple and RTD calibrator, thermocouple and RTD calibrator (PT100), calibrate thermocouple instruments to 0.1 and 0.01, °F and °C

  • Consultation Hotline:18615230752   Landline:0531-88975421

CL543B thermocouple and RTD calibrator, thermocouple and RTD calibrator (PT100), calibrate thermocouple instruments to 0.1 and 0.01, °F and °C

Product Overview

[CL543B Thermocouple and RTD Calibrator — Features]

Thermocouple and RTD calibrator (PT100)

Calibrate thermocouple instruments to 0.1 and 0.01, °F and °C

Types J, K, T, E, R, S, B, N, G, C, D, L (J-DIN), (T-DIN), and P (Platinel): -13.000 to 80.000 mV

Calibrate RTD instruments to 0.1 and 0.01, °F and °C

Pt 10, 50, 100, 200, 500, and 1000 (3850)

Pt 100 (alpha = 3902, 3916, 3926)

Cu 10 and 50 as well as Ni 120

Calibrate with confidence

Resolution of 0.01, °F and °C; accuracy to 0.2°

Cold junction sensor accurate to 0.05°C

NIST-traceable cold junction sensor in isothermal block

Troubleshoot RTD sensors and instruments

Auto-detects 2-wire, 3-wire, or 4-wire connections; indicates when individual wire connection is open

Verify correct instrument operation by measuring excitation current

Quick and easy calibration

Instantly select 3 outputs using EZ-CHECK switch

Easily find trip points using 2-speed EZ-DIAL knob and auto-step

Verify resistance, cold junction temperature, and output

Secondary display of resistance for RTD and compensated mV settings, as well as cold junction temperature for thermocouples

For factory, field, or shop

Includes rubber boot and mV test leads

Slim switches prevent accidental damage

Brass screw and mini thermocouple socket for thermocouple wires

Perform heat treatment surveys and accuracy tests

Meets or exceeds AMS 2750 requirements as a secondary standard instrument and field test instrument

NIST certificate (no points)

Thermocouple Connection

Simulating or reading thermocouples requires the use of thermocouple or extension-grade thermocouple wire. Insert the thermocouple wire into the mini thermocouple jack or place the bare thermocouple wire under the brass block below the screw.

The CL543B thermocouple and RTD calibrator has two banana jacks (1+ and 2-) mounted on top of the housing. These are not temperature compensated and are for mV signal only.

RTD (PT100) Connection

Simulating or reading RTDs uses copper wire. Insert 2-wire, 3-wire, or 4-wire into the corresponding jacks on the calibrator. For RTD source, the CL543B simulates the (+) RTD from jacks 1 and 4 and the (−) RTD from jacks 2 and 3. When reading an RTD sensor, the CL543B thermocouple and RTD calibrator automatically detects whether it is a 2, 3, or 4-wire connection using proprietary circuitry. This aids in troubleshooting sensor connections.