Welcome to Shandong Proud Measurement&Control Technology CO., LTD!

186-1523-0752

0531-88975421

Popular product search:
Click to enlarge

[Wed 2026-07-29 14:45 GMT+8] CL514-PLUS platinum RTD calibrator

Product Introduction:

CL514-PLUS platinum RTD calibrator, Omega USA platinum RTD calibrator, CL514-PLUS measures or simulates platinum resistance sensors for multiple RTD curves, automatic universal platinum RTD calibrator, measures or simulates platinum resistance sensors for multiple RTD curves.

  • Consultation Hotline:18615230752   Landline:0531-88975421

CL514-PLUS platinum RTD calibrator, Omega USA platinum RTD calibrator, CL514-PLUS measures or simulates platinum resistance sensors for multiple RTD curves, automatic universal platinum RTD calibrator, measures or simulates platinum resistance sensors for multiple RTD curves.

Product Overview

CL514-PLUS Platinum RTD Calibrator — Features

Automatic universal platinum RTD calibrator

Measures or simulates platinum resistance sensors for multiple RTD curves

Easy-to-read backlit display

Auto-detects 2, 3, and 4-wire connections

Fast calibration using auto output stepping

Protected by rugged rubber boot

Calibrate directly in temperature (°C or °F)

Compatible with all RTD process instruments

With the CL514-PLUS platinum RTD calibrator, you can check and calibrate all RTD instruments and measure RTD sensors. Connections are automatically indicated on the display for easy hookup. Take it to the shop, factory, or field with confidence. It features a rubber boot and rugged slim-line switches for protection. Easy to operate even in dark areas of the plant with a backlit display. Stop carrying decade boxes and RTD resistance tables — calibrate directly in temperature (°C or °F). The CL514-PLUS accommodates a variety of RTD curves, including Platinum 100 (alpha = 3850, 3902, 3926) and 1000 (alpha = 3850, 3750) Ω, Copper 10 and 50 Ω, Nickel 100 and 120 Ω. Use the adjustable digital potentiometer “DIAL” to quickly set any value within 0.1°, and store any three temperatures for instant recall. Fast calibration with auto output stepping. Choose 2, 3, 5, 11, and 21 steps, automatically incrementing output by 100%, 50%, 25%, 10%, or 5%. Choose step time that matches your system: 5, 6, 7, 8, 10, 15, 20, 25, 30, and 60 seconds. Directly connect to RTD inputs of smart transmitters, PLCs, controllers, and multi-channel recorders, and verify their output or display. Measure and troubleshoot RTD sensor connections and find open wires. Connect a 2, 3, or 4-wire RTD sensor, and the CL541-PLUS automatically measures the RTD in °C or °F.